3. UPC: Current Stock: This item is out of stock. Contraindications There are no known contraindications. Mechanical Aspiration Thrombectomy Using the Penumbra CAT RX - PubMed The four cathetersCAT3, 5, 6, & 8are robust, durable, trackable, and suited for the peripheral anatomy. Penumbra Aspiration Pump The Penumbra Aspiration Pump is indicated as a vacuum source for Penumbra Aspiration Systems. The Penumbra ENGINE is indicated as a vacuum source for Penumbra Aspiration Systems. Potential Adverse Events The treatment of arterial and venous thrombus is challenging. Disclosures: Consultant to Penumbra, Inc. A 59-year-old man with a history of hypertension and tobacco use presented with an inferior-posterior acute myocardial infarction (MI). Contraindications There are no contraindications. 1. Penumbra Announces U.S. Commercial Availability of INDIGO System Penumbra Indigo Aspiration System IDE Trial for Acute Pulmonary Thrombus aspiration in patients with high thrombus burden in the TOTAL trial. The cerebral vasculature Indigo System CAT RX tracking through the distal posterior tibial artery. The Indigo CAT RX Aspiration Catheters and Indigo Separator 4: Related Items. Return all damaged devices and packaging to the manufacturer/distributor. The sustained aspiration power provided by the Penumbra ENGINE allowed rapid TIMI 3 flow restoration and removal of the distal emboli. The patient vomited the ticagrelor within 2 hours of administration and cangrelor was started. With reperfusion to the distal vasculature and clear visualization of the underlying stenosis, a 3.5-mm stent was placed. After one pass with mechanical thrombectomy using CAT RX, the thrombus was removed and flow was restored to the pedal arch via the plantar posterior tibial artery (Figure 2 and Figure 3). The Indigo System Catheter CAT8 was used across 22 sites in the United States in patients with submassive PE who did not receive thrombolytics (98.3%), with a . Penumbra ENGINE Indication For Use Catheters; CAT8 KIT Indigo System Aspiration Catheter 8 and Aspiration Tubing - XTORQ - 8Fr x 115cm . Mathews SJ, Brown C, Kolski B, et al. The product-specific content of this website is intended for use by healthcare professionals only. This is potentially more effective than diminished syringe-based aspiration. CAT8 Indigo System Aspiration Catheter - TORQ - 8Fr x 85cm Penumbra System. gtag('config', 'UA-18982160-1'); Penumbra Inc .cls-1{fill:#a6a699;}.cls-2{fill:#b5121b;}.cls-3{isolation:isolate;fill:url(#linear-gradient);}. Maintain a constant infusion of appropriate flush solution. This press release features multimedia. St. Joseph Hospital Equipment is not safe for MR use. 22. Distal OD, Sterile, Single-Use, Disposable, For CAT8 Penumbra Devices, Indigo Aspiration Catheters, Removal of Fresh, Soft Emboli and Thrombi from Vessels of Peripheral Arterial and Venous Systems She had a recent embolic cerebrovascular accident (CVA) with a hemorrhagic conversion and right-sided hemiparesis but was otherwise known to be very functional. In our practice, we have been able to more accurately define percutaneous transluminal coronary angioplasty and stent length as a result of this increased visualization. The Penumbra P logos, 3D, 3D Revascularization Device, ACE, BENCHMARK, CAT, Indigo, LANTERN, MAX, Neuron, Neuron MAX, Penumbra ENGINE, Penumbra JET, Penumbra System, Penumbra SMART COIL, POD, Ruby, Separator, Velocity, and WAVE are registered trademarks or trademarks of Penumbra, Inc. in the USA and other countries. The Indigo System utilizes the Penumbra ENGINEaspiration source capable of delivering nearly pure, continuous vacuum (-29 inHg or 98.2 kPa) to our catheters, enabling thrombus removal in vessels of various sizes. Final angiogram showing resolution of extensive thrombus burden. Potential Adverse Events Possible complications include, but are not limited to, the following: allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arrhythmia/fibrillation; arteriovenous fistula; death; device malfunction; distal embolization; emergent surgery; false aneurysm formation; hematoma, hemorrhage, or blood loss at access site; hematoma, hemorrhage, or blood loss; hypotension; inability to completely remove thrombus or control blood flow; infection; ischemia; kidney damage from contrast media; myocardial infarction; neurological deficits including stroke; respiratory failure; thromboembolic events; vascular complications (including vessel spasm, thrombosis, intimal disruption, dissection, or perforation). Disclosures: None. Do not use petroleum base compounds, acids, caustics, or chlorinated solvents to clean or lubricate any parts. This website is intended for US audience only. INDIGO SEPARATOR 4 is intended to be used with INDIGO CAT RX Aspiration Catheter to clear the distal end of the catheter lumen should it be blocked with thrombus. Results of EXTRACT-PE Trial presented at Vascular InterVentional Advances (VIVA) Annual Meeting Penumbra, Inc. (NYSE: PEN), a global healthcare company focused on innovative therapies, today announced that the EXTRACT-PE trial successfully met the primary endpoints, demonstrating the safety and efficacy of the Indigo Aspiration System for aspiration mechanical thrombectomy in patients with . gtag('js', new Date()); Indigo Aspiration Catheters (CAT) are the foundation of Penumbras IndigoSystem. The pain became more intense and constant, so he presented to the ED. Unrestrained torquing or forced insertion of the catheter or SEPARATOR against resistance may result in damage to the device or vessel. Pharmacomechanical catheter-directed thrombolysis for deep-vein thrombosis. Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the Penumbra ENGINE. Penumbra CAT8TORQ85 CAT8 Indigo Aspiration Catheter 8, TORQ tip, 85cm Do not use in the presence of a flammable anesthetic mixture with air or nitrous oxide. CAT8 Indigo Aspiration Catheter 8, TORQ tip, 85cm , 8Fr., Peripheral Thrombectomy Mechanical one eachCAT8 Indigo Aspiration Catheter 8, TORQ tip, 85cm , 8Fr., Peripheral Thrombectomy Mechanical one eachCAT8 Indigo Aspiration Catheter 8, TORQ tip, 85cm , 8Fr., Peripheral . Penumbra's high-performance aspiration catheters. excellent trackability, and similar power to the CAT8 Penumbra catheter that was previously used for this . Hemoglobin and hematorcrit levels should be monitored in patients with >700 mL blood loss from the clot aspiration procedure. If the cause cannot be determined, withdraw the device or system as a unit. The combination of computer-aided aspiration and large-lumen catheter engineering form Lightning 7 and Lightning 12: the latest generation in clot removal technology. The Indigo System CAT RX with Penumbra ENGINE is an invaluable tool that is easy to set up and can provide rapid thrombectomy and immediate reperfusion. Figure 3. 0, 23. Only use replacement fuse with correct rating (see Table 1 for fuse rating). Vascular Thrombectomy. MAUDE Adverse Event Report: PENUMBRA, INC. INDIGO SYSTEM CAT 8 Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 12 inches (30 cm) to any part of LIGHTNING Aspiration Tubing. Possible complications include, but are not limited to, the following: allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arteriovenous fistula; death; device malfunction; distal embolization; emboli; false aneurysm formation; hematoma or hemorrhage at access site; inability to completely remove thrombus; infection; hemorrhage; ischemia; kidney damage from contrast media; neurological deficits including stroke; vessel spasm, thrombosis, dissection, or perforation; intimal disruption; myocardial infarction; emergent surgery; fibrillation; hypotension; respiratory failure; peripheral thromboembolic events. Do not use the Indigo Aspiration System with a pump other than the Penumbra Aspiration Pump. The cat8 was kinked approximately 69. Previous Article, Single-Access Technique for Impella-Assisted High-Risk PCI. Enter your email address and we will contact you. The advantages of CAT RX with Penumbra ENGINE include the potential to remove the thrombus intact and reduce the potential of systemic embolization while also increasing the visualization of the underlying stenosis and distal vessel. The procedure was completed with the same catheter. Cook Medical) with the Indigo System (Penumbra, Inc.) using a CAT8 catheter and SEP8 separator to maximise the debris removal. The INDIGO Aspiration System is intended for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and certain central circulatory system conditions such as pulmonary emboli using continuous aspiration. Figure 2. Jolly SS, Cairns JA, Yusuf S, et al. Learn more about Lightning. Figure 1. Penumbra Aspiration Pump: The Penumbra Aspiration Pump is indicated as a vacuum source for Penumbra Aspiration Systems. Figure 1. Do not resterilize or reuse. The Indigo System CAT3, CAT5, CAT6, CAT8, CATD, and CAT7D are engineered to be robust, trackable, atraumatic, and well suited for the peripheral anatomy. Available in a selection of sizes, the CAT family can enable access to distal peripheral vessels of the upper and lower extremities, including below the knee. With S. Jay Mathews, MD, MS, FACC; Chris Metzger, MD; Waqas R. Qureshi, MD, MS; Jawairia Sahar K. Mirza, MBBS; Gus Theodos, MD, FACC, FSCAI; Brian Kolski, MD; and Suhail Dohad, MD, FACC. INDIGO CAT RX Aspiration Catheters and INDIGO SEPARATOR 4 Indication for Use As part of the INDIGO Aspiration System, the INDIGO CAT RX Aspiration Catheters and INDIGO SEPARATOR 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature.
For Rent No Credit Check Las Vegas, Air Cooled Vw Fuel Injection Kit, Kraken Margin Trading Ecp, Articles C